E41-874 · Seal Component Selection · Chemical Process Pump · ★★★★★
One chemical pump (mechanical seal) dead-headed to 2.5 MPa at the outlet, exceeding the seal's 1.6 MPa rating; the faces blew open with heavy leakage, a splash hazard.
First, mechanical seal face pressure p_b=β·p_m+p_s, p_m = chamber pressure; here p_m=2.5 MPa exceeds design 1.6 MPa. Second, p_b exceeds the face liquid film load capacity → film breaks, dry friction, face temperature rise and deformation; leakage q surges. Third, overpressure extrudes the spring seat O-ring and fails the seal. Root cause: chamber pressure exceeds the seal rating.
① Verify chamber pressure ≤ rating when selecting a seal (single seal ≤1.6 MPa; double seal with barrier fluid can be higher)
② For overpressure service use a double mechanical seal + barrier fluid (barrier pressure >chamber pressure by 0.1–0.2 MPa)
③ Install a relief valve at the pump outlet to limit pressure ≤ seal rating
④ Add a buffer tank to stabilize large chamber pressure fluctuations
⑤ Check the seal pressure-temperature curve when selecting
⑥ Do not run over-pressure
⑦ Add pressure monitoring with overpressure alarm
FT_Seal Spring Design