Knowledge Base › Selection Error Cases › Wrong Step Seal Spec Mating Causing Extrusion (Injection Molding Machine)

Wrong Step Seal Spec Mating Causing Extrusion (Injection Molding Machine)

E41-878 · Seal Component Selection · Injection Molding Clamp Cylinder · ★★★★

Problem Description

One injection molding machine clamp cylinder (21 MPa) had a wrong step seal energizing O-ring spec (undersize wire); the PTFE ring was extruded and sheared, clamp force was insufficient, and parts were scrapped.

Root Cause

First, a step seal = PTFE ring + energizing O-ring; the O-ring wire must match the groove to give pre-compression δ=15–20%. Here the O-ring wire was too small giving only 5% pre-compression, leaving the PTFE ring with no back pressure. Second, chamber pressure 21 MPa pushes the PTFE ring into the gap; without O-ring push it shears. Third, after shearing sealing force drops, clamp force fluctuates, and parts are scrapped. Root cause: wrong energizer spec.

Corrective Solution

① The step seal O-ring wire must match the groove to give 15–20% pre-compression
② When selecting step seals, check the matched O-ring spec table (do not substitute)
③ Verify O-ring wire d2 and groove depth before assembly
④ Add backup rings at high pressure to prevent PTFE extrusion
⑤ Do not force or damage the PTFE ring at assembly
⑥ Check the O-ring cross-section each time
⑦ If clamp force is unstable, check the step seal immediately

Checklist