E41-880 · Seal Component Selection · Food Filling Machine · ★★★★

Problem Description

One food filling machine used plain NBR seals; harmful substances migrated, non-food-grade components were detected in the product, and the whole batch was recalled.

Root Cause

First, plain NBR contains migratable vulcanizing agents and plasticizers; contacting food does not meet GB4806. Second, oily media raise plasticizer extraction and exceed limits. Third, recall loss + brand damage. Root cause: non-food-grade material used.

Corrective Solution

① Food/pharma contact must use food-grade materials (silicone/food-grade EPDM/PTFE, with GB4806 or FDA)
② Specify food contact on selection and require certificates
③ Do not use plain NBR/reclaimed rubber in food
④ Material must be low-extractable and steam-sterilizable
⑤ Keep a material certificate ledger
⑥ Require and verify certificates per batch
⑦ Non-compliance risks whole-batch recall