E41-882 · Seal Component Selection · Reactor Agitator Shaft Seal · ★★★★★
One reactor's twin seal barrier fluid tank level dropped and the pump stopped; faces ran dry and leaked, and highly toxic medium from the reactor escaped, a hazard.
First, a twin mechanical seal relies on barrier fluid to form a film between the faces; barrier pressure must be >reactor pressure by 0.1–0.2 MPa. Second, tank level drop makes barrier pressure fall below reactor pressure; medium back-flows and faces run dry. Third, dry running raises face temperature >200°C, cracking and leaking. Root cause: barrier system failed without monitoring.
① Twin seals must have a barrier fluid system; barrier pressure >medium pressure by 0.1–0.2 MPa and stabilized
② Add level/pressure interlocks on the barrier tank; alarm and refill on low
③ Use barrier fluid compatible with the medium, clean, high lubricity
④ Verify face pressure vs. barrier pressure on selection
⑤ Add differential pressure monitoring; stop when barrier pressure <reactor pressure
⑥ Check level / refill periodically
⑦ For highly toxic media add double protection + leak collection