Knowledge Base › Selection Error Cases › Wrong O-Ring Wire Diameter Selected (Standardization Error)

Wrong O-Ring Wire Diameter Selected (Standardization Error)

E41-885 · Seal Component Selection · Standardization Error · ★★

Problem Description

One design mistakenly used a 2.65 wire ring in place of 3.53 (same inner diameter); compression δ changed from 20% to 10%, causing low-pressure leakage.

Root Cause

First, O-rings of the same inner diameter come in different wire d2; compression δ=(d2-h)/d2 varies with d2. After substitution δ=10%< the lower limit, giving insufficient contact stress. Second, at low pressure 0.5 MPa, σ_c<0.5 → leaks. Third, confused standardization caused batch errors. Root cause: wrong wire substitution.

Corrective Solution

① Do not mix/substitute O-rings of the same inner diameter but different wire; select by drawing number
② Build a standardized O-ring spec library (inner diameter × wire unique)
③ Any substitution must recalculate compression δ=(d2-h)/d2
④ Design must annotate d2, not just inner diameter
⑤ Verify wire diameter on the BOM
⑥ Do not pull parts by approximate inner diameter
⑦ Standardization review

Checklist