E42-151 · Stiffness Insufficient · TH6350 Horizontal Machining Center · ★★★
Machined 800 mm flatness 0.06 mm (allow 0.02); CMM recheck showed 0.15 mm settlement difference across foundation corners, column tilt 0.03°.
[Insufficient foundation stiffness] only 4 anchor bolts eccentrically on one side; C20 concrete foundation settles Δ=0.15 mm under 28 t load. [Tilt transfer] column tilts 0.03° with foundation; spindle axis lower end drifts 0.12 mm / 400 mm stroke. [Design omission] anchor bolts not symmetrically/uniformly distributed; no equipment foundation laid.
1. Change anchor bolts to 8, uniformly distributed, spacing ≤600 mm.
2. Change foundation to C30 reinforced concrete, thickness ≥300 mm.
3. Add adjustable shim packs at column base, 3 per group, load-uniform.
4. Level with frame level to 0.02 mm/m at installation.
5. Anchor grout layer strength ≥M20.
6. Add anti-rotation dowels at spindle head-to-column joint.
7. Daily check foundation settlement; re-level if >0.05 mm.
8. Track flatness over 72 h continuous machining before shipment.
GB 50040-2020