E42-453 · Insufficient Stiffness · Wind Turbine Yaw Support · ★★
The 2MW wind turbine yaw support plate thickness 10mm deforms 2.3mm; tower sway ±0.5° exceeds the 0.2 allowance; 2 shutdowns per month
[Flexible Support] Thin support plate, stiffness K=3MN/m is too low; natural frequency 5Hz is close to wind frequency.
[Vibration] Tower-top displacement amplified.
[Design Omission] Support stiffness not verified, no stiffeners added; safety factor 1.3 (should be ≥2.0).
1) Thicken support plate to 16mm;
2) Add longitudinal stiffeners;
3) Raise stiffness to 6MN/m;
4) Detune yaw frequency from wind frequency;
5) Measure deformation each quarter;
6) Limit tower-top sway;
7) Preload bolts;
8) Periodic re-measurement.
GB/T 19072-2010