E42-004 · Vibration & Resonance · CNC Lathe CK6140 · ★★★

Problem Symptom

At 1200rpm the surface shows chatter marks Ra3.2 (allowable 1.6) and the condition cannot be avoided

Root Cause

[System Natural Frequency] The bed has an equivalent mass m=2200kg and an equivalent stiffness k=9.0e7N/m, so the natural frequency is f=√(k/m)/2π=√(9e7/2200)/6.28=32.2Hz.
[Excitation Match] The spindle at 1200rpm equals 20Hz, and the 4-pole motor's line frequency of 100Hz and its 32Hz harmonic coincide with the 32.2Hz natural frequency, with an amplification factor Q=12.
[Design Omission] No vibration isolation was fitted between the motor and the bed and the bed was not locally stiffened; in the resonance zone the chatter Ra3.2 is 2 times out of tolerance.

Correct Solution

1) Install rubber vibration-isolation pads between motor and bed (stiffness ≤3e6N/m);
2) Stiffen the local motor pedestal of the bed to raise local stiffness;
3) Avoid the resonance speed band (mark 1150-1250rpm as a red forbidden zone);
4) Set the inverter jump frequency to stay away from 32Hz;
5) Dynamically balance the spindle to G1.0;
6) Add anti-loosening to the bed levelling feet and re-grout;
7) Sample-inspect the roughness of machined surfaces;
8) Archive the vibration modal analysis report and include it in design review.

Checklist

References

GB/T 16768-2010 Metal Cutting Machine Tools — Measurement of Vibration