Insufficient Rotor Dynamic Balance Causes Excessive 1x Vibration

E42-104 · Vibration & Resonance · Centrifugal Compressor CENTAC · ★★★

Problem Symptom

1x vibration velocity 8.5mm/s (allowable 4.5), bearing temperature rise 12℃, interlock trip

Root Cause

[Unbalance Centrifugal Force] The residual unbalance of the impeller is U=800g·mm at n=15000rpm; the centrifugal force F=U(2πn/60)²/r excites 1x vibration.
[Resonance Amplification] The natural frequency of the foundation is close to the line frequency, and the transmissibility amplification raises the vibration velocity to 8.5mm/s.
[Design Omission] The impeller was not dynamically balanced as a complete assembly (G6.3 insufficient) and the foundation was not vibration-isolated.

Correct Solution

1) Dynamically balance the impeller as a complete assembly to G2.5;
2) Carry out field balancing to reduce the 1x component;
3) Install damping vibration isolators on the foundation;
4) Keep the foundation natural frequency away from 0.8~1.2 times the line frequency;
5) Monitor bearing housing vibration online with alarm;
6) Set the trip thresholds in accordance with API 617;
7) Add an interlock on the lubricant temperature;
8) Include the vibration value in the shutdown protection.

Checklist

References

API 617 Petroleum, Chemical and Gas Industry — Centrifugal Compressors

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »