E42-106 · Vibration & Resonance · Screw Air Compressor 90kW · ★★
The outlet pipe shakes violently near the pulsation main frequency, the flange seal leaks oil and a branch pipe fractures
[Gas Column Natural Frequency] The pipe length is L=6m and the sound speed is c≈340m/s, so one order of the gas column natural frequency coincides with the main pulsation frequency of the gas flow.
[Resonance Amplification] The gas pulsation matches the natural frequency of the pipe structure, and the amplified amplitude loosens the flange through fatigue and leaks oil.
[Design Omission] No combined acoustic and structural simulation was done for the piping and no expansion joint was fitted.
1) Install a bellows expansion joint to absorb the pulsation;
2) Add supports to the piping and change the span to shift the frequency;
3) Add fixed supports on the elbows to reduce swinging;
4) Fit a pulsation attenuator at the outlet;
5) Tighten the flanges to the specified torque and re-inspect;
6) Simulate the piping modal frequencies to stay clear of the pulsation frequency;
7) Detect leaks online;
8) Include piping vibration in the commissioning.
GB/T 3853 Positive Displacement Compressors — Acceptance