Knowledge Base › Structural Design Error Case Study › Fan Blade Passing Frequency and Housing Resonance

Fan Blade Passing Frequency and Housing Resonance

E42-335 · Vibration and Resonance · Centrifugal Fan Impeller · ★★

Problem Description

Centrifugal fan blade passing frequency resonates with housing; noise 95dB; 2 units repaired per month

Root Cause

[Blade Passing Frequency] Blade passing frequency f=12×25=300Hz coincides with housing mode; resonance.
[Noise] Radiated noise 95dB.
[Design Omission] No modal analysis; tip clearance too small; safety factor only 1.2.

Corrective Solution

1) Change blade number to 13 to detune frequency;
2) Add housing stiffeners to avoid frequency by ≥20%;
3) Enlarge tip clearance;
4) Impeller dynamic balance G6.3;
5) Modal analysis each batch;
6) Acoustic treatment;
7) Limit speed;
8) Periodic inspection.

Checklist

Reference

GB/T 1236-2017