Knowledge Base › Structural Design Error Case Study › Hydraulic Power Unit Tank Wall Pump Vibration Radiation

Hydraulic Power Unit Tank Wall Pump Vibration Radiation

E42-456 · Vibration and Resonance · Hydraulic Power Unit Tank · ★★

Problem Description

Hydraulic power unit (pump 45kW) tank wall amplitude 0.4mm; noise 88dB exceeds limit; weld loosens once a month

Root Cause

[Pump Vibration] Pump rotor unbalance force F=200N; excitation 45Hz close to wall panel natural.
[Radiation] Thin wall radiates noise.
[Design Omission] No ribs; no isolation; safety factor 1.5 (should be ≥2.0).

Corrective Solution

1) Add rib plates to tank wall;
2) Add rubber isolation to pump;
3) Raise wall thickness to 8mm;
4) Add flexible hoses to inlet/outlet pipes;
5) Measure vibration monthly;
6) Limit pump speed;
7) Apply damping to wall;
8) Periodic re-measurement.

Checklist

Reference

GB/T 3766-2015