E42-505 · Vibration and Resonance · Centrifugal Fan (4-72) · ★★★

Problem Description

At speed 1450rpm, impeller natural frequency 24.2Hz resonates with blade passing frequency 24.1Hz; amplitude 8mm/s exceeds 4.5 allowance; 2 shutdowns per month

Root Cause

[Resonance] Blade passing frequency f=24.1Hz ≈ natural fn=24.2Hz; resonance amplified.
[Frequency Difference] Impeller stiffness low; no dynamic balance.
[Design Omission] No modal analysis; no frequency avoidance; safety factor 1.5 (should be ≥2.0).

Corrective Solution

1) Add impeller ribs to raise stiffness;
2) Detune natural frequency by ≥15%;
3) Conduct whole-machine dynamic balance;
4) Measure vibration each shift;
5) Limit speed ±5%;
6) Add damping ring;
7) Impeller flaw detection;
8) Periodic vibration recheck.