Knowledge Base › Structural Design Error Case Study › Crane Drum Shaft Fatigue Crack

Crane Drum Shaft Fatigue Crack

E42-507 · Fatigue Fracture · Overhead Crane (32t) · ★★★

Problem Description

Drum shaft diameter 120mm, stress amplitude σa=110MPa, crack at shoulder after 2×10^6 cycles; 2 hoist shutdowns per year

Root Cause

[Fatigue] Stress amplitude σa=110MPa; shoulder r=2mm stress concentration Kt=2.1; Goodman check n=0.9<1.
[Crack Source] Surface tool marks; no flaw detection.
[Design Omission] No fatigue check; R fillet too small; safety factor 1.1 (should be ≥1.5).

Corrective Solution

1) Raise shoulder R to 8mm;
2) Surface roll strengthening;
3) Perform magnetic-particle inspection;
4) Check cracks each shift;
5) Limit lifting load to ≤28t;
6) Improve material quenching and tempering;
7) Stress-relief annealing;
8) Periodic shaft recheck.

Checklist

Reference

GB/T 3811-2008