Problem Description

Porosity at the tooth root after machining; uneven hardness.

Root Cause

[Chill Misalignment] The chill is too far from the hot spot, so cooling there is slow and solidification lags. [Local Porosity] The hot spot does not solidify first, leaving interdendritic shrinkage. [Design Omission] Chill placement based on experience, no solidification simulation.

Corrective Solution

1. Place chills against hot spots within ≤20mm.
2. Use solidification simulation to locate chills.
3. Add blind risers for feeding.
4. Control pouring temperature.
5. UT inspect the teeth.
6. Section each batch to check porosity.
7. 100% hardness check for uniformity.
8. Freeze the process documents.

Checklist

Reference

GB/T 1348-2019