E42-285 · Threaded Fastener Loosening · Flange Bolt Group · ★★
The flange bolt group tightened by feel; preload scatter ±40%; uneven seal leaks; 4 leak repairs per month
[Large Scatter] Tightened by feel; preload scatter ±40%; uneven seal specific pressure.
[Leakage] Local specific pressure below gasket yield causes weeping; bolt group loaded off-center.
[Design Omission] No torque method, no calibration; seal reliability only 0.7 (should be ≥0.95).
1) Calibrate torque wrench ±3%;
2) Tighten in 2~3 cross-pattern passes;
3) Control preload scatter ±10%;
4) Add pressure-equalizing gaskets;
5) Sampling torque check each batch;
6) Locking marks;
7) Certified assembly training;
8) Retightening ledger.
GB/T 16823.2-1997