E42-409 · Threaded Fastener Loosening · DG85-80 Multistage Centrifugal Pump Outlet Flange · ★★
DG85-80 pump outlet DN150 flange M20 bolts loosen under pulsating pressure; interface weeps 2L/min; repaired 3 times per month
[Pulsation Loosening] Medium pulsation makes the flange move slightly; preload drops 20%. [Weeping] Insufficient specific pressure; gasket fails. [Design Omission] No spiral-wound gasket, no locking; safety factor 1.2 (should be ≥1.5).
1) Change gasket to spiral-wound metal gasket;
2) Add spring washers to bolts;
3) Control flange parallelism ≤0.2mm;
4) Cross-pattern multi-pass tightening;
5) Leak detection every shift;
6) Add a pressure surge tank;
7) Limit operating conditions;
8) Periodic re-torque.
GB/T 9119-2010