E42-415 · Stress Concentration · MQ4035 Main Girder Lower Flange · ★★
MQ4035 gantry main girder lower flange process cutout (un-ground) r=1mm crack 60mm; handled at monthly inspection
[Cutout] Lower flange opening r=1mm; Kt=2.5. [Fatigue] Hoisting alternation σ=160MPa; life 50k cycles (design 120k). [Design Omission] Cutout not ground smooth; not reinforced; safety factor 1.2 (should be ≥1.8).
1) Grind cutout R≥5mm;
2) Add reinforcing plate;
3) Magnetic-particle cutout;
4) Limit lifting load;
5) Dynamic load test;
6) Add strain monitor;
7) Shot peen;
8) Periodic NDE.
GB/T 28264-2012