E42-025 · Thermal Distortion & Thermal Stress · Machining Center Motorized Spindle · ★★★
Continuous running raises the temperature by 25℃, axial elongation 0.03mm, and Z-axis accuracy drifts by 0.02
[Thermal Elongation] With spindle length L=400mm, α=1.2e-5 and ΔT=25, the elongation is ΔL=αLΔT=1.2e-5×400×25=0.12mm, of which 0.03mm is effectively reproduced.
[Accuracy Impact] The 0.03mm axial elongation maps directly onto Z-axis positioning, exceeding the allowable 0.01 by two times.
[Design Omission] There is no thermal compensation and no cooling, so the accuracy drifts.
1) Constant-temperature spindle cooling at 23±1;
2) Install a linear scale for thermal compensation;
3) Pre-stretch the spindle to offset the elongation;
4) Carry out a thermal stability run-in;
5) Monitor temperature measuring points;
6) Carry out a warm-up accuracy check;
7) Tune the compensation parameters;
8) Include thermal error compensation in the machine tool accuracy acceptance.
GB/T 17421 Thermal Errors of Machine Tools