E42-422 · Thermal Deformation and Thermal Stress · F3015 Laser Cutting Machine Bed · ★★★
F3015 laser bed (length 3000) servo temperature rise ΔT=10℃, bed deflection 0.04mm, kerf misalignment; 3 repairs per month
[Temperature Rise] Linear motor temperature rose 10℃, bed elongated 0.36mm on one side. [Deformation] Guideway parallelism lost 0.03mm. [Design Omission] No symmetrical cooling and no compensation; safety factor 1.3 (should be ≥2.0).
1) Symmetrical cooling circuit for the bed;
2) Add a thermal insulation cover;
3) Thermal error compensation;
4) Control ambient temperature ±1℃;
5) Measure temperature every shift;
6) Limit the power gradient;
7) Re-measure accuracy in hot state;
8) Run in a constant-temperature room.
GB/T 18400.1-2010