E42-427 · Thermal Deformation and Thermal Stress · Oil Temperature Machine Flange Joint · ★★

Problem Description

Mold temperature controller (200℃) oil circuit flange thermally expanded and displaced 0.3mm, joint leaked; 4 repairs per month

Root Cause

[Thermal Expansion] Oil temperature 200℃, pipe flange expanded and displaced 0.3mm. [Leakage] Seal specific pressure lost, oil leaked. [Design Omission] No compensation and rigid connection; safety factor 1.3 (should be ≥2.0).

Corrective Solution

1) Add metal flexible pipe compensation;
2) Add spring washers to the flange;
3) Change seal to graphite spiral-wound gasket;
4) Sliding supports for pipe racks;
5) Leak detection every shift;
6) Limit temperature;
7) Thermal insulation;
8) Periodic re-torque.

Checklist

Reference

GB/T 25157-2010