E42-182 · Impact and Overload Fracture · High-speed centrifuge rotor · ★★★
Counterweight bolt fractured during operation, weight flew out and cracked housing.
[Detachment] Counterweight held only by adhesive; centrifugal force detached it. [Impact] Weight struck housing at v=45m/s, local stress exceeded strength. [Design Omission] No mechanical locking, no dynamic-balance re-check; housing shattered and injured people.
1. Counterweight mechanically bolted plus pin double-locked.
2. Adhesive as auxiliary only.
3. Rotor dynamically balanced to G2.5.
4. Add armor plate to housing.
5. Provide overspeed protection.
6. Use lock tabs on bolts.
7. Periodic check of counterweight loosening.
8. Housing impact alarm.
GB/T 9239.1-2006