Knowledge Base › Structural Design Error Case Study › Rotor Counterweight Detachment Causing Housing Impact and Fracture

Rotor Counterweight Detachment Causing Housing Impact and Fracture

E42-182 · Impact and Overload Fracture · High-speed centrifuge rotor · ★★★

Problem Description

Counterweight bolt fractured during operation, weight flew out and cracked housing.

Root Cause

[Detachment] Counterweight held only by adhesive; centrifugal force detached it. [Impact] Weight struck housing at v=45m/s, local stress exceeded strength. [Design Omission] No mechanical locking, no dynamic-balance re-check; housing shattered and injured people.

Corrective Solution

1. Counterweight mechanically bolted plus pin double-locked.
2. Adhesive as auxiliary only.
3. Rotor dynamically balanced to G2.5.
4. Add armor plate to housing.
5. Provide overspeed protection.
6. Use lock tabs on bolts.
7. Periodic check of counterweight loosening.
8. Housing impact alarm.

Checklist

Reference

GB/T 9239.1-2006