Loose Transition Fit Causes Micro-Movement and Loosening of the Locating Pin

E42-134 · Fit & Interference Failures · Machine Tool Fixture Locating Pin Bore · ★★

Problem Symptom

The transition fit is on the loose side and the locating repeatability of 0.05mm is out of tolerance

Root Cause

[Loose Fit] The bore and pin are on the loose side of the transition fit, so a clearance remains after assembly and the pin moves slightly.
[Loosening] Cutting vibration causes micro-movement and wear in the pin bore, so the accuracy is lost.
[Design Omission] A close transition or light press fit was not selected and the retention force was not calculated.

Correct Solution

1) Change to a light press fit (H7/p6);
2) Add a taper to the locating pin for a wedging fit;
3) Calculate the fit retention force;
4) Ream the pin bore to preserve accuracy;
5) Re-test the repeatability;
6) Fix with thread-locking adhesive against loosening;
7) Check the wear amount periodically;
8) Include the fit selection in the fixture design.