Poor Mounting Datum Flatness Twists the Linear Guide and Causes Sticking

E42-138 · Linear Guide Accuracy · Machining Center Linear Guide · ★★

Problem Symptom

Mounting datum flatness 0.05mm, the carriage sticks and produces noise

Root Cause

[Datum Error] A flatness of 0.05 on the bed mounting face leaves the two rails non-parallel and twisted.
[Sticking] The preload is uneven on the twisted rails, so the carriage sticks and produces noise.
[Design Omission] The datum was not scraped and the parallelism was not measured.

Correct Solution

1) Scrape the bed datum face to a flatness of ≤0.01;
2) Keep the parallelism of the two rails at ≤0.01 over the full length;
3) Check the span consistency with a mandrel;
4) Tighten the rail bolts to the specified torque in sequence;
5) Measure the carriage moving force;
6) Align with a straight edge and dial indicator during installation;
7) Set the preload to the manufacturer curve;
8) Include the datum face in the assembly requirements.

Checklist

References

JB/T 2256 Jig Boring Machines — Inspection of Accuracy