Feed Line Guide Pitch Deviation

E42-445 · Guideway Alignment Accuracy · Feeder X-direction guide · ★★

Problem Description

Stamping line feed guideway (pitch 500): straightness 0.05mm, accumulated pitch error 0.1mm over allowable 0.03, double-blank; repaired 3 times a month

Root Cause

[Poor straightness] Feed guideway straightness 0.05mm, accumulated pitch offset. [Double-blank] Positioning inaccuracy, double feed. [Design Omission] No calibration, no feedback; safety factor 1.3 (should be ≥2.0).

Corrective Solution

1) Calibrate guideway straightness ≤0.02mm;
2) Add linear-encoder pitch feedback;
3) Set datum stop;
4) Pitch check each shift;
5) Limit feed speed;
6) Add double-blank detection;
7)Preload;
8) Periodic re-measurement.

Checklist

Reference

GB/T 23281-2009

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »