Poor Foundation Stiffness Causes Excessive Vibration at the Machine Feet

E42-049 · Structural Instability & Buckling · Floor Boring and Milling Machine Foundation · ★★★

Problem Symptom

Foot vibration of 4mm/s, causing chatter marks on the workpiece

Root Cause

[Foundation Stiffness] The concrete foundation has a natural frequency f_b≈18Hz, close to the machine frequency f_m≈20Hz, and modal coupling amplifies it by about 2 times.
[Coupled Vibration] The feet transmit amplified vibration up to 4mm/s (allowable 2.8).
[Design Omission] The foundation was not designed and no vibration isolation was provided, so chatter marks appeared.

Correct Solution

1) Thicken the reinforced concrete foundation;
2) Add an isolation trench;
3) Grout the machine feet a second time;
4) Separate the modal frequencies;
5) Measure vibration to ≤2.8mm/s;
6) Carry out a trial run;
7) Perform acceptance;
8) Include foundation dynamics in machine installation design.

Checklist

References

GB 50040 Code for Design of Foundations of Power Machines

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL