E42-484 · Structural Instability and Buckling · Hydraulic prop · ★★★
Hydraulic prop (φ100, L=4000): compression buckled 8mm, unstable; 1 piece scrapped monthly
[Buckling] Slenderness λ=4000/25=160>100, critical Pcr=π²EI/L²=60kN below working.
[Bend] Instability.
[Design Omission] No slenderness limit, no upsizing; safety factor 1.2 (should be ≥3.0).
1) Upsize column to 140mm;
2) Limit slenderness ≤100;
3) Add intermediate support;
4) Upgrade material;
5) Pressure test each batch;
6) Limit working load;
7) End fixed support;
8) Periodic re-measurement.
GB/T 3766-2015