Knowledge Base › Structural Design Error Case Study › Truss Compression Chord Instability

Truss Compression Chord Instability

E42-486 · Structural Instability and Buckling · Truss chord · ★★★

Problem Description

Truss (span 24m): compression chord instability bend, collapse risk; 1 near-accident monthly

Root Cause

[Chord instability] Slenderness λ=150>120, Pcr below working load bent.
[Collapse] Chain reaction.
[Design Omission] No slenderness limit, no double-limb; safety factor 1.2 (should be ≥3.0).

Corrective Solution

1) Change chord to double-limb;
2) Limit slenderness ≤120;
3) Enlarge section;
4) Add lacing bars;
5) Verify each truss bent;
6) Limit working load;
7) Rigid node connection;
8) Periodic re-measurement.

Checklist

Reference

GB/T 50017-2017

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »