Substituting Aluminium for Steel Leaves Insufficient Strength Margin and Causes Fracture

E42-045 · Insufficient Strength in Lightweight Design · Aluminium Bracket · ★★★

Problem Symptom

The aluminium bracket fractured under load

Root Cause

[Strength Ratio] Aluminium has σ_s=200 against 350 for steel, so at equal wall thickness the safety factor n=1.2 is below 2.
[Safety Factor] With n=1.2 insufficient, the part fractured under load.
[Design Omission] The material was substituted directly without recalculation, so the part broke.

Correct Solution

1) Increase the section thickness by 30% or add reinforcement;
2) Recalculate to a safety factor of ≥2;
3) Change to a high-strength 7xxx aluminium alloy;
4) Reinforce the connections;
5) Carry out finite element analysis;
6) Run a bench test;
7) Perform flaw detection;
8) Include material substitution in the strength recalculation process.

Checklist

References

GB/T 3190 Wrought Aluminium Alloys