E42-094 · Insufficient Strength in Lightweight Design · Magnesium Alloy Housing AZ91D · ★★
The part crushed under load
[Wall Thickness] A 3mm magnesium alloy wall has insufficient compressive capacity.
[Crushing] The part yielded and crushed.
[Design Omission] Compressive capacity was not checked and the wall was too thin, so the part crushed.
1) Increase the wall thickness to 5mm;
2) Check the compressive stability;
3) Add ribs for reinforcement;
4) Upgrade the material;
5) Distribute the load;
6) Optimise the mould flow;
7) Carry out a proof pressure test;
8) Make compressive capacity a mandatory calculation.
GB/T 5153-2016 Wrought Magnesium and Magnesium Alloys