E42-144 · Insufficient Strength in Lightweight Design · Drone Carbon Fibre Shell · ★★
The lay-up angles are wrong and the strength in the load direction is only 50% of the design
[Wrong Lay-up] No 0° layer is placed in the main load direction and the proportion of off-axis layers is wrong, so the axial strength is low.
[Insufficiency] The modulus and strength in the load direction reach only 50% of the design value.
[Design Omission] The lay-up was not designed along the load path and no simulation was carried out.
1) Re-lay the 0° / ±45° layers according to the load path;
2) Check the strength by lay-up simulation;
3) Add unidirectional fabric in the critical zones;
4) Control the temperature during curing;
5) Re-test the tensile properties on coupons;
6) Use NDT to detect delamination;
7) Position the fibre angle by laser;
8) Include the lay-up in composite design.
GB/T 1446 Fibre Reinforced Plastics — Methods of Testing Properties