Knowledge Base › Structural Design Error Case Study › Thin-Walled Steel Frame Welded Corner Cracking

Thin-Walled Steel Frame Welded Corner Cracking

E42-323 · Insufficient Lightweight Strength · Thin-walled steel frame · ★★

Problem Description

Thin-wall steel frame (δ=2): welded corner cracked, accuracy lost; 4 pieces scrapped monthly

Root Cause

[Thin-wall crack] δ=2mm thin, weld shrinkage stress σ=300MPa exceeded yield.
[Corner crack] Corner stress concentration, cracking.
[Design Omission] No corner reinforcement, no deformation control; safety factor only 1.2.

Corrective Solution

1) Add triangular reinforcement plate at corners;
2) Use spot welding to reduce heat input;
3) Pre-set distortion compensation;
4) Change material to Q355;
5) NDE each batch;
6) Deformation correction;
7) Limit welding speed;
8) Periodic inspection.

Checklist

Reference

GB/T 700-2006