Knowledge Base › Structural Design Error Case Study › Magnesium Housing Mounting Ear Fracture

Magnesium Housing Mounting Ear Fracture

E42-325 · Insufficient Lightweight Strength · Magnesium alloy housing · ★★

Problem Description

Magnesium alloy housing (AZ91D): mounting ear fractured, leaked; 3 pieces scrapped monthly

Root Cause

[Thin ear] Ear wall 3mm, concentrated stress σ=90MPa exceeded.
[Crack] Vibration fatigue fracture.
[Design Omission] No ear thickening, no fillet; safety factor only 1.2.

Corrective Solution

1) Thicken ear to 6mm;
2) Fillet r≥3mm;
3) Add radial ribs;
4) Change material to AZ80;
5) FE check;
6) Limit vibration;
7) NDE each batch;
8) Periodic inspection.

Checklist

Reference

GB/T 5153-2016