Knowledge Base › Structural Design Error Case Study › Welded Frame Aging Deformation

Welded Frame Aging Deformation

E42-546 · Residual Stress Deformation · Welded frame · ★★

Problem Description

No aging after welding, resting deformation 1.0mm over allowable 0.3, hard to assemble; 3 pieces returned monthly

Root Cause

[Residual deformation] Welding residual σ=200MPa, released deformation 1.0mm.
[Not aged] Un-treated.
[Design Omission] No aging, no stress relief; safety factor 1.3 (should be ≥2.0).

Corrective Solution

1)Vibration stress relief;
2) Thermal aging;
3) Stress-relief annealing;
4) Deformation check each piece;
5) Limit welding sequence;
6) Symmetric welding;
7) Add rigid clamp;
8) Periodic re-measurement.

Checklist

Reference

JB/T 5926-2005