Unmachined Assembly Datum Causing Accumulated Error

E42-499 · Other · Box assembly · ★★

Problem Description

Reducer housing assembly datum not machined, accumulated error 0.15mm, gear noise; 4 units returned monthly

Root Cause

[Missing datum] Assembly base not machined, roughness Ra=12.5, accumulated error 0.15mm.
[Abnormal noise] Mesh offset.
[Design Omission] No datum, no accumulation control; safety factor 1.4 (should be ≥2.0).

Corrective Solution

1) Mill the base surface;
2) Control roughness Ra≤3.2;
3) Set unified datum;
4) Accumulated error ≤0.05;
5) Datum inspection each batch;
6) Limit stack-up layers;
7) Add dowel pins;
8) Periodic re-measurement.

Checklist

Reference

GB/T 1184-1996