Excessive Raceway Clearance in a Slewing Bearing Causes Radial Runout

E43-133 · Improper Clearance Fit · Tower Crane Slewing Bearing · ★★

Problem Symptom

The clearance between the raceway and the balls was designed at 0.05mm but measured 0.20mm; the 0.5mm radial runout made the tower sway

Root Cause

[Large Clearance] The design clearance was 0.05mm, but raceway wear made the actual clearance 0.20mm.
[Radial Runout] The large clearance gave 0.5mm of radial runout during slewing, beyond the limit, so the positioning was poor.
[Design Omission] The clearance should have been controlled to ≤0.06mm with preload provided, but wear was not controlled.

Correct Solution

1) Control the clearance to ≤0.06mm;
2) Fit preload bolts;
3) Harden the raceway;
4) Measure the radial runout;
5) Verify the positioning against the runout;
6) Tighten the bolts periodically;
7) Inspect the slewing gear mesh;
8) Spot-check every batch.