Excessive Compressor Piston Clearance Causes Reed Valve Impact

E43-142 · Improper Clearance Fit · Refrigeration Compressor · ★★

Problem Symptom

The clearance between the piston and the cylinder was designed at 0.05mm but measured 0.18mm; the large dead volume made the reed valves strike and produced noise

Root Cause

[Large Clearance] The design clearance was 0.05mm, but cylinder wear made the actual clearance 0.18mm.
[Reed Valve Impact] With the large clearance the piston travel at bottom dead center increased, the reed valves were struck and their life shortened.
[Design Omission] The clearance should have been controlled to ≤0.06mm with the dead volume measured, but wear was not controlled.

Correct Solution

1) Control the clearance to ≤0.06mm;
2) Measure the dead volume;
3) Mirror finish the cylinder bore;
4) Measure reed valve life;
5) Verify against the dead volume;
6) Replace the cylinder regularly;
7) Keep the refrigerant clean;
8) Spot-check every batch.

Checklist

References

GB/T 1801-2009 Limits and Fits