Insufficient Harmonic Drive C Spline-to-Housing Interference Causes Noise

E43-189 · Interference Fit Failures · Robot Harmonic Drive C Spline ∅80, designed interference 0.03mm, measured 0.01mm · ★★

Problem Symptom

The loose C spline made the transmission noisy and the backlash large, so the positioning accuracy suffered

Root Cause

[Mechanism] The insufficient interference let the C spline micro-move under alternating deformation and the gear ring shifted.
[Calculation] δ≥0.025 is needed to lock the C spline; the measured 0.01 gives p=0.01×2.1e5/80=26MPa, which is insufficient and allowed micro-motion.
[Design Omission] The fit was not selected as H7/n6 and the interference was not controlled; this design flaw caused noise.

Correct Solution

1) Raise the interference to 0.03~0.04;
2) Select H7/n6;
3) Assemble cold on a press to guarantee the interference;
4) Check the backlash;
5) Judge seating by the assembly sound;
6) Group and select parts by the measured sizes;
7) Re-tighten periodically;
8) Carry out a backlash test on the first piece.

Checklist

References

GB/T 5371-2004 Interference Fits — Calculation and Selection