Insufficient Agitator Blade-to-Shaft Interference Causes the Blade to Come Off

E43-199 · Interference Fit Failures · Reactor Agitator Shaft ∅80, designed interference 0.06mm, measured 0.02mm · ★★

Problem Symptom

The insufficient interference let the blade loosen under the reaction torque of the viscous medium and the agitation stopped

Root Cause

[Mechanism] The insufficient interference let the blade micro-move and loosen under the reaction torque of the viscous resistance.
[Calculation] δ≥0.05 is needed to transmit 1.2kNm; the measured 0.02 gives p=0.02×2.1e5/80=53MPa, which is insufficient.
[Design Omission] No set screws were provided and the interference was not controlled; this design flaw allowed the blade to come off.

Correct Solution

1) Raise the interference to 0.06~0.08;
2) Fit set screws;
3) Select H7/n6;
4) Assemble cold on a press to guarantee the interference;
5) Tighten to the specified torque;
6) Check that the fastening is seated;
7) Re-tighten periodically;
8) Carry out a torque test on the first piece.