E43-403 · Transition Fit Selection Error · sprocket bore ø45 selected H7/k6 transition, design should be H7/p6+key transmitting 200N·m · ★★★
Sprocket transition fit made key shear one-sided, key fractured during operation, chain came off.
[Mechanism] Transition fit has insufficient interference; torque borne mainly by key causing key shear stress to exceed.
[Calculation] Key shear τ=T/(d·b·l/2)=200000/(45×12×40/2)≈18.5MPa exceeding key material allowable 12.
[Design Omission] Insufficient interference to share load, design defect → key fracture.
1) Change to H7/p6 interference to share 60% torque;
2) Widen key to b=14 to lower shear stress;
3) Symmetric keyway machining;
4) Control roughness to preserve μ;
5) Calculate press-fit force;
6) Select high-grade tolerance;
7) Torque monitoring against overload;
8) First-article torque test verifies no key fracture.
GB/T 1095-2003 Flat keys — Cross-section dimensions for keyways