Sprocket Shaft Transition Fit Key Fracture

E43-410 · Transition Fit Selection Error · drive sprocket shaft ø35 with wheel selected H7/k6 transition, design should be H7/p6+key · ★★

Problem Description

Sprocket transition fit made key shear by impact, drive interrupted.

Root Cause

[Mechanism] Transition fit has insufficient interference; impact load borne entirely by key in shear causing fracture.
[Calculation] Key shear τ=T/(d·b·l/2)=150000/(35×10×36/2)≈23.8MPa exceeding allowable 12.
[Design Omission] Impact sprocket did not use interference to share load, design defect → key fracture.

Corrective Solution

1) Change to H7/p6 interference to share torque;
2) Widen key to lower shear stress;
3) Make keyways symmetric;
4) Control surface roughness;
5) Press-fit verification;
6) Select a stable tolerance grade;
7) Impact monitoring;
8) First-article torque test verification.

Checklist

Reference

GB/T 1095-2003 Flat keys — Cross-section dimensions for keyways