Knowledge Base › Tolerance and Fit Error Case › Crankshaft Pulley Transition Fit Loosening

Crankshaft Pulley Transition Fit Loosening

E43-419 · Transition Fit Selection Error · crankshaft pulley ø50 with shaft selected H7/js6 transition, design should be H7/p6 interference · ★★

Problem Description

Pulley transition fit loosened, timing offset, belt jumped.

Root Cause

[Mechanism] Timing pulley needs precise locating; transition fit unstable interference fretting causes timing offset.
[Calculation] Timing offset θ=Δs/r, δ_min=2×T/(π·d·l·μ·E)≈0.01mm; js6 can have zero interference.
[Design Omission] Timing pulley wrongly chosen transition fit, design defect → pulley loosening.

Corrective Solution

1) Change timing pulley to H7/p6 interference;
2) Add a key to prevent rotation;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit positioning;
6) Select a stable tolerance grade;
7) Timing light inspection;
8) First-article timing verification.

Checklist

Reference

GB/T 11361-2018 Synchronous belt drive