Flange Connection Transition Fit Misalignment

E43-422 · Transition Fit Selection Error · flange connection ø150 bore-shaft selected H7/js6 transition, design should be clearance H8/f8 locating · ★★

Problem Description

Flange wrongly chosen transition fit made bolt holes misaligned, seal offset.

Root Cause

[Mechanism] Flange relies on bolt-hole clearance for locating; transition fit lacks sufficient clearance causing bolts not to pass and misalignment.
[Calculation] Required clearance Xmin≥0.5mm for bolt passage; js6 limit clearance only 0.04mm far insufficient.
[Design Omission] Flange connection wrongly chosen transition fit, design defect → hole misalignment.

Corrective Solution

1) Change flange to H8/f8 clearance locating;
2) Leave clearance ≥0.5 per bolt diameter;
3) Control coaxiality;
4) Select a stable tolerance grade;
5) Match-drill to preserve hole position;
6) Sealing surface flatness;
7)Trial assemblyBolt;
8) First-article hole position ≤0.5mm.