E43-424 · Transition Fit Selection Error · indexer cam ø35 with shaft selected H7/js6 transition, design should be H7/p6 for indexing · ★★★
Indexer cam transition fit fretting made indexing phase offset 1°, positioning wrong.
[Mechanism] Indexer relies on cam interference to set phase; transition fit unstable interference fretting causes phase offset.
[Calculation] Index offset Δ=π·D·Δθ/360, δ_min=2T/(π·d·l·μ·E)≈0.006mm; js6 can be zero.
[Design Omission] Indexer cam wrongly chosen transition fit, design defect → phase offset.
1) Change the cam to H7/p6 interference;
2) Add a pin to prevent rotation;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit positioning;
6) Select a stable tolerance grade;
7) Dividing-head instrument check;
8) First-article indexing verification ≤0.5°.
GB/T 1800.2-2020 Geometrical Product Specifications (GPS) — Limits and fits