MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Tolerance and Fit Error Case › Mixing Shaft Transition-Fit Loosening

Mixing Shaft Transition-Fit Loosening

E43-430 · Transition Fit Selection Error · Mixing shaft ø50 with impeller selected H7/k6 transition, should be H7/p6 to transmit torque · ★★

Problem Description

The impeller blades loosened and slipped under the transition fit, causing uneven mixing.

Root Cause

[Mechanism] The impeller relies on interference to transmit torque; insufficient transition-fit interference causes slipping.
[Calculation] δ_min=2×T/(π·d·l·μ·E)=2×150000/(π×50×60×0.12×2.1e5)≈0.0126mm; k6 is unstable.
[Design Omission] The mixing impeller was wrongly given a transition fit; design defect → loosening.

Corrective Solution

1) Change the impeller to H7/p6 interference;
2) Add a key to prevent slipping;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit verification;
6) Select a stable tolerance grade;
7) Torque monitoring;
8) First-article run-in test verification.

Checklist

Reference

GB/T 1800.2-2020 Geometrical Product Specifications (GPS) — Limits and fits

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL