E43-436 · Transition Fit Selection Error · Magneto rotor ø30 with shaft selected H7/js6 transition, should be H7/p6 to maintain phase · ★★★
Fretting from the rotor transition fit shifted the ignition phase and caused the engine to lose step.
[Mechanism] The magneto rotor relies on interference to hold ignition phase; unstable transition-fit interference frets and causes lost step.
[Calculation] Ignition shift Δθ corresponds to δ_min≈0.004mm; js6 can be zero with unstable interference.
[Design Omission] The magneto rotor was wrongly given a transition fit; design defect → lost step.
1) Change the rotor to H7/p6 interference;
2) Add a Woodruff key to prevent rotation;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit positioning;
6) Select a stable tolerance grade;
7) Ignition timing check;
8) First-article phase measured ≤1°.
GB/T 1800.2-2020 Geometrical Product Specifications (GPS) — Limits and fits