Gear Pump Ring Gear Transition-Fit Trapped Oil

E43-440 · Transition Fit Selection Error · Gear pump ring gear ø80 with body selected H7/k6 transition, should be H7/p6 for locating · ★★

Problem Description

Fretting from the ring-gear transition fit caused eccentricity, trapped oil, noise and pressure pulsation.

Root Cause

[Mechanism] The gear-pump ring gear needs interference locating to hold eccentricity; unstable transition-fit interference frets and traps oil.
[Calculation] Eccentricity e=0.03mm makes meshing clearance uneven and traps oil; δ_min≈0.012mm; k6 can be zero.
[Design Omission] The gear-pump ring gear was wrongly given a transition fit; design defect → trapped oil.

Corrective Solution

1) Change the ring gear to H7/p6 interference;
2) Add a pin to prevent rotation;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit positioning;
6) Select a stable tolerance grade;
7) Noise monitoring;
8) First-article eccentricity measured ≤0.01mm.

Checklist