E43-015 · Geometrical Tolerance Errors · Pipe Flange Connection · ★★
Flange face runout 0.10mm; the gasket was crushed unevenly and leaked; 20 maintenance interventions per month
[Perpendicularity] Flange face perpendicularity to the axis was 0.10 (allowable 0.03); after the bolts were tightened the gasket was locally crushed.
[Leakage] Uneven gasket compression left the local specific pressure below the 4MPa required for sealing, so the medium leaked through.
[Design Omission] Perpendicularity should be ≤0.03 with a spiral wound gasket, and no end-face turning calibration was performed.
1) Control flange face perpendicularity to ≤0.03 to prevent uneven loading and leakage;
2) Turn and calibrate the end face to guarantee flatness and preserve sealing;
3) Select a spiral wound gasket to absorb unevenness and accommodate the misalignment;
4) Pre-tighten the bolts uniformly in a diagonal sequence to prevent distortion;
5) Calibrate the preload with a torque wrench to prevent loosening;
6) Check the end face for scoring before assembly to guarantee contact;
7) Perform a pressure test and confirm no leakage to verify sealing;
8) Bring perpendicularity into the flange acceptance criteria.
GB/T 9124-2019 Steel Pipe Flanges — Technical Conditions