E43-062 · Geometrical Tolerance Errors · Centrifugal Pump Impeller · ★★
Impeller end-face runout was designed at 0.02 but measured 0.10; the sealing face wore unevenly and leaked
[Large Runout] The design end-face runout was 0.02 but the actual was 0.10 because weld distortion was not accounted for.
[Seal Leakage] The runout made the mechanical seal rotating ring wobble, so the end-face specific pressure was uneven and the seal leaked.
[Design Omission] End-face runout should have been specified and corrected by turning after welding, but no runout inspection was done.
1) Reduce impeller end-face runout to 0.02 to preserve sealing;
2) Correct the runout by turning after welding;
3) Dynamically balance to reduce vibration;
4) Keep sealing face flatness ≤0.01 to guarantee contact;
5) Select the spring force according to the specific pressure to prevent over-tightening;
6) Monitor with a runout tester;
7) Replace the seal periodically to prevent leakage;
8) Re-turn out-of-specification impellers.
GB/T 1182-2018 Geometrical Tolerances