E43-214 · Geometrical Tolerance Errors · Horizontal Boring Machine Boring Fixture · ★★
Column perpendicularity to the base 0.05mm (allowable 0.02) shifted the bored hole axis
[Mechanism] Insufficient scraping during fixture assembly tilted the column.
[Calculation] A perpendicularity of 0.05 produced an offset of 0.05×150/300=0.025 at a boring depth of 150, above the 0.02 allowable.
[Design Omission] No column scraping or perpendicularity check was done; this design flaw caused the hole drift.
1) Scrape the column to perpendicularity ≤0.02;
2) Check with a set square and blueing;
3) Level the base;
4) Verify the perpendicularity with a test-bored workpiece;
5) Tighten the fastenings with even force;
6) Re-verify periodically;
7) Re-measure after reassembly;
8) Bring perpendicularity into the assembly inspection.
GB/T 1182-2018 Geometrical Tolerances